Filter Results By:

Products

Applications

Manufacturers

Showing results: 121 - 135 of 145 items found.

  • NI-9238, ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module

    783311-01 - NI

    ±500 mV, 50 kS/s/ch, 24-Bit, Simultaneous Input, 4-Channel C Series Voltage Input Module - The NI‑9238 performs differential analog input. The measurement range is compatible with many low-voltage sensors such as current shunts and current transducers in high-current applications. When used with higher-voltage C Series Voltage Input Modules, the NI‑9238 can measure power and energy consumption for applications such as appliance test, industrial machine monitoring, power quality analysis, phasor measurements, and harmonic analysis.

  • Autonomous RTUs

    Infinite Industrial Informatics Lt

    Autonomous RTUs are power network independent devices, opening up new horizons for telemetry in off-grid areas. An autonomous RTU features in measuring capabilities and contains a wireless MODEM for data and alarm transmission. It can also provide all necessary circuits for powering measuring transducers and sensors. The device is commonly powered by an internal battery and is housed in a IP66 to IP68 enclosure for outdoor use. The battery lifetime requirements extend from few months to 15 years. Another common requirement is continuous, maintenance free operation in harsh environmental conditions and extended temperature ranges.

  • Load Cell Transmitter

    MODEL SST-HV - Transducer Techniques, Inc

    The SST-HV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-HV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-HV may be powered from 95-240 Vac ±10%. The SST-HV has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • Load Cell Transmitter

    MODEL SST-LV - Transducer Techniques, Inc

    The SST-LV is a Plug & Play Smart TEDS IEEE 1451.4 compliant Transmitter. Just plug in a TEDS compatible Load Cell or Torque Sensor and the SST-LV will automatically self-calibrate. When used with a non-TEDS Load Cell or Torque Sensor, the SST-LV Transmitter is easily programmed using a PC with an RS232 port and Instrument Setup (IS) software, which provides a graphical user interface. The SST-LV may be powered from 12-30 Vac or 10-48 Vdc. The SST-HV Has an Isolated transducer excitation output that is selectable between 5Vdc or 10Vdc. There are Dual solid state relays and an Isolated 4-20 mA, 0-20 mA or 0-10V analog output. There are three Isolated serial data transmitter output ( RS232 , Half-duplex RS485, full-duplex RS485 ) and three serial protocols that are software selectable (Modbus RTU, Modbus ASCII and Custom ASCII). Isolation to 250V rms is provided for power, signal input, analog output, relay outputs, and communications. Isolation adds safety and avoids possible ground loops. The transducer excitation output is isolated to 50V from signal ground.

  • Lan-Xi Data Acquisition Hardware

    Brüel & Kjær Sound & Vibration A/S

    LAN-XI modules can function individually, and can use battery power to create small, rugged, low channel count systems of up to 12 channels. You can attach many different types of front input panels to connect the transducers of your choice. Around each connector is a circular LED that shows the channel's use and health at a glance backed up with an LCD screen. A key feature is the Dyn-X technology, which avoids the need for input ranging by using dual A/D converters to ensure you get the data the first time while achieving an effective dynamic range of over 160 dB.

  • Temperature and Pressure

    Encore Electronics, Inc.

    Encore Electronics manufactures a complete line of rugged and economical instrumentation for temperature and pressure measurement. Our standard, in-stock units can be used for pressure measurement depending on the signal level and output required. Our equipment is available in both DIN rail and modular/rack-mounted configurations for multiple channel capability. Simply specify your output — whether 4 to 20mA , 0 to 10V, or a custom output and Encore can configure a system to match your needs. Whether you need isolated input and outputs using transducer power or computer-controlled units, we will design and build a unit to meet your requirement.

  • NI-9375 , 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module

    781030-01 - NI

    30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.

  • NI-9375, 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module

    781030-02 - NI

    30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.

  • NI-9375, 30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module

    785192-01 - NI

    30 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The NI‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The NI‑9375 offers isolation between the input and output banks from channel‑to‑earth ground.

  • Meter Test & Calibration

    Kongter Test & Measurement Co., Limited

    Kongter offers a whole line of products for meter test and calibration including portable power source, standard reference meter and meter test system. All products are accredited to the highest production standards with different options of measurement accuracy (class 0.05 and class 0.1).These enable them to cover different applications for test and calibration of different types of energy meters, electric transducers, indicating meters and so on.

  • PXI/PXIe LVDT, RVDT, Resolver Simulator Modules

    Pickering Interfaces Ltd.

    Linear variable differential transformers (LVDT) are electrical transformer sensors to measure linear displacement. Driven by an AC excitation source, the LVDT generates a pair of AC output signals modulated according to the core's mechanical position (displacement). LVDTs have been widely used in applications such as power turbines, hydraulics, automation, aircraft, satellites, nuclear reactors, and many others. These transducers have low hysteresis and excellent repeatability.

  • sbRIO-9375, Non-Enclosed, 24 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module

    781212-01 - NI

    Non-Enclosed, 24 V, 32-Channel (Sinking Input, Sourcing Output), 7 µs (Input)/500 µs (Output) C Series Digital Module - The sbRIO‑9375 is a digital I/O interface that works with industrial logic levels and signals for direct connection to a wide array of industrial switches, transducers, and other devices. Each digital input line is compatible with 24 V logic levels, and all the output lines are compatible with 6 V to 30 V signals, based on the external power supply. The sbRIO‑9375 offers isolation between the input and output banks from channel‑to‑earth ground. Non-enclosed modules are designed for OEM applications.

  • One Phase Electric Power/Energy Calibrator

    MC133 - Powertek LLC

    The MC133 master unit model is a one phase electric power/energy calibrator. It can supply the device under test with single phase precise voltage and current with calibrated phase shift along with DC voltage and current capability. Output voltage can be set in five ranges up to 280V and output current in six ranges up to 30A. Simulated electric power can be set independently for each phase. Frequency can be set from 15Hz to 1 kHz with resolution 0.001Hz to 0.01Hz. The MC133 Calibrator is equipped with 5 1/2 digital DC meter with DC ranges 20mA or 10V for direct calibration of various types of power transducers and wattmeters.

  • Circuit Breaker Analyzers & Timers

    IBEKO Power AB

    CAT circuit breaker analyzers and timers are advanced standalone or a PC controlled instruments for circuit breaker maintenance. Typical application areas of CAT instruments are medium and high voltage substations at electric power generation, transmission, and factories of switchgear. Also, industrial environments and electric power distribution are suitable application areas for these circuit breaker testing instruments.DV Power CAT circuit breaker testing instruments are portable and lightweight. They are designed for performing mechanical operations intended for circuit breakers testing according to standards IEC 62271-100 and IEEE C37.09.These instruments measure:the timing of main contacts, pre-insertion resistor contacts, auxiliary contacts operations,coil currents,motion parameters,voltage recording,main circuit resistance,arcing contacts wipe,and any relevant analog signal.Motion transducer channels provide measuring a displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time, and average velocity. Even more, CAT circuit breaker analyzer optionally has a built-in micro-ohmmeter. Hence, it provides the main circuit resistance measurement and dynamic resistance measurement. Dynamic resistance measurement is an effective method for arcing contacts condition assessment.

  • Load Cell Power Supply

    MODEL PSMR - Transducer Techniques, Inc

    The PSM-R is a self contained AC power bridge excitation supply. This device consists of a low interwinding capacitance AC transformer and a high stability adjustable linear regulator designed specifically for driving transducer bridges. DC excitation is adjustable from 4 to 15 volts output and is capable of supplying 0 to 150 mA in output current. It features remote sensing to eliminate line drop errors and very low noise. It can also be used as a high quality voltage source or reference in many applications. AC input requirements are 105 to 125 VAC at 60 Hz.

Get Help